TwoPassSincResampler.java

package builder.resid.resample;

/**
 * Compose a more efficient SINC from chaining two other SINCs.
 *
 * @author Antti Lankila
 */
public class TwoPassSincResampler implements StereoResampler {
    private final SincResampler s1, s2;

    public TwoPassSincResampler(double clockFrequency, double samplingFrequency, double highestAccurateFrequency) {
        /*
         * Calculation according to Laurent Ganier. It evaluates to about 120 kHz at
         * typical settings. Some testing around the chosen value seems to confirm that
         * this does work.
         */
        double intermediateFrequency = 2 * highestAccurateFrequency + Math.sqrt(2 * highestAccurateFrequency
                * clockFrequency * (samplingFrequency - 2 * highestAccurateFrequency) / samplingFrequency);
        s1 = new SincResampler(clockFrequency, intermediateFrequency, highestAccurateFrequency);
        s2 = new SincResampler(intermediateFrequency, samplingFrequency, highestAccurateFrequency);
        reset();
    }

    @Override
    public boolean input(int sample) {
        return s1.input(sample) && s2.input(s1.output());
    }

    @Override
    public boolean input(int sampleL, int sampleR) {
        return s1.input(sampleL, sampleR) && s2.input(s1.outputL(), s1.outputR());
    }

    @Override
    public int output() {
        return s2.output();
    }

    @Override
    public int outputL() {
        return s2.outputL();
    }

    @Override
    public int outputR() {
        return s2.outputR();
    }

    @Override
    public void reset() {
        s1.reset();
        s2.reset();
    }
}